Clearly identify the location of your Fire Department Connection (FDC) shut-off valve with this compliant signage. Required under NYC Fire Code, this sign ensures rapid emergency response by guiding FDNY personnel to critical fire protection controls, helping prevent delays during fire suppression operations.
Dimensions: 7" x 10"
Materials: Printed Vinyl Mounted on to .03125in Aluminum
What This Sign is For: The FDC Shut-Off Valve Location sign is used to direct emergency responders to the exact location of the shut-off valve controlling the Fire Department Connection (FDC).
In many buildings, the shut-off valve is not immediately visible or located directly next to the FDC. This sign provides clear directional guidance, ensuring that fire personnel can quickly locate and operate the valve during an emergency.
Legal Requirement Explained: Under the NYC Fire Code (FC §901, §903, §912) and applicable NFPA standards, all fire protection system components—including FDCs and their associated control valves—must be clearly identified and accessible.
When the shut-off valve is not in the immediate vicinity of the FDC, signage is required to indicate its location and distance. This ensures that the Fire Department can quickly locate and control water supply connections without delay, which is critical during fire suppression efforts.
Who is Required to Post This Sign:
- Buildings equipped with a Fire Department Connection (FDC)
- Properties where the FDC shut-off valve is located remotely from the connection point
- Commercial buildings
- High-rise buildings
- Multifamily residential buildings with fire protection systems
- Any structure with standpipe and/or sprinkler systems connected to an FDC
Where We Recommend This Sign Be Posted:
- At or directly adjacent to the Fire Department Connection (FDC)
- In a position that clearly indicates the direction and/or distance to the shut-off valve
- On an exterior wall or surface visible from the street or fire department access point
- At a location where it can be easily seen by FDNY personnel upon arrival
Unacceptable Locations to Post This Sign:
- In locations where it is not visible from the FDC or approach path
- Behind obstructions such as landscaping, parked vehicles, or equipment
- Inside rooms or areas not accessible during an emergency
- On surfaces that may be covered, blocked, or removed
- In poorly lit or concealed areas that reduce visibility
Recommended Height / Installation Requirements:
- Install at eye level (typically 48”–60” above finished floor/grade)
- Must be permanently mounted using durable materials suitable for exterior conditions
- Lettering must be clearly legible and of sufficient size for visibility at a distance
- Use high-contrast colors (commonly red/white) for quick identification
- Ensure the sign remains unobstructed and well-maintained over time
Disclaimer: The information provided is based on commonly referenced provisions of the NYC Fire Code and NFPA standards. Specific requirements may vary depending on building type, system configuration, and jurisdictional updates. Always consult with a licensed professional or the Authority Having Jurisdiction (AHJ), such as the FDNY, to confirm compliance for your specific project.