Ensure compliance with NYC fire safety codes using a “Fire Door Keep Closed” sign. Required for fire-rated doors, this sign helps prevent the spread of smoke and fire by reminding occupants to keep doors closed at all times, supporting safe egress and proper compartmentalization.
Dimensions: 7" x 10"
Materials: Printed Vinyl Mounted on to .03125in Aluminum
What This Sign is For: A “Fire Door Keep Closed” sign is used to clearly indicate that a fire-rated door must remain closed at all times to maintain its fire-resistance function. These doors are critical for preventing the spread of fire and smoke, protecting escape routes, and maintaining building compartmentalization during emergencies.
Legal Requirement Explained: Under the NYC Fire Code (FC §703) and NFPA 80 (Standard for Fire Doors and Other Opening Protectives), fire-rated doors must be properly maintained and kept closed unless equipped with an approved automatic closing device. Signage is required to clearly communicate this requirement to occupants and building personnel, ensuring that fire doors are not improperly propped open or obstructed.
Who is Required to Post This Sign:
- Commercial buildings
- Multifamily residential buildings
- High-rise buildings
- Buildings with designated fire-rated corridors or separations
- Any structure containing fire-rated doors without automatic hold-open devices
Where We Recommend This Sign Be Posted:
- Directly on the fire door itself
- On the occupant-facing side of the door
- In a location that is clearly visible when approaching the door
- On doors leading to stairwells, corridors, mechanical rooms, and fire-rated separations
Unacceptable Locations to Post This Sign:
- Mounted away from the door (e.g., adjacent wall instead of the door surface)
- Placed on the non-visible side of the door
- Obstructed by hardware, push bars, or other signage
- Installed in a way that is not readable when the door is closed
- Using temporary, faded, or non-durable materials
Recommended Height / Installation Requirements:
- Typically installed at eye level (48”–60” above finished floor)
- Must be securely affixed to the door surface (adhesive or mechanical fastening)
- Lettering must be clear, legible, and contrasting with the background
- Sign must remain visible and unobstructed at all times
- Should not interfere with door operation or fire rating
Disclaimer: This information is provided for general guidance based on commonly referenced NYC Fire Code and NFPA standards. Specific requirements may vary depending on building type, occupancy classification, and local authority interpretations. Always consult with a licensed professional or the NYC Department of Buildings (DOB) and FDNY for project-specific compliance requirements.