Photoluminescent Running Man exit signs provide clear, code-compliant egress guidance during emergencies and power outages. Required in many NYC high-rise buildings, these glow-in-the-dark signs enhance visibility in low-light conditions, helping occupants safely navigate exit routes in accordance with NYC Building Code requirements. UL 1994 Listed Photoluminescent Markings on Green Background.
Dimensions: 5.875" x 5.875"
Materials: .03125in Aluminum w/ Self-Adhesive Foam Back
What This Sign is For: The Photoluminescent Running Man Sign is used to clearly indicate the direction of an exit path during emergencies, particularly when lighting conditions are compromised. The universally recognized “running man” symbol provides intuitive, visual guidance that helps occupants quickly identify and follow the safest path to an exit.
Legal Requirement Explained: This sign is required under the NYC Building Code §1025, which mandates photoluminescent exit path markings in high-rise buildings. These systems must remain visible without electricity, ensuring that occupants can safely exit during power failures, fires, or smoke conditions when traditional lighting may be unavailable.
Who is Required to Post This Sign:
- High-rise buildings (generally 75 feet or taller)
- Commercial office buildings
- Residential high-rise buildings
- Hotels and mixed-use developments
- Any building required to install a photoluminescent exit path system
Where We Recommend This Sign Be Posted:
- Along designated exit paths and egress routes
- At key decision points where direction must be clarified
- Near stairwell entrances and exits
- In corridors leading to exits
- As part of a continuous photoluminescent egress system
Unacceptable Locations to Post This Sign:
- In areas that do not lead to an exit or approved egress path
- Where visibility is blocked by doors, furniture, or equipment
- In locations with insufficient ambient light to charge the photoluminescent material
- Randomly placed without alignment to the actual exit direction
- In isolation without integration into a complete egress marking system
Recommended Height / Installation Requirements:
- Typically installed at low-level heights (approximately 12”–18” above finished floor) as part of NYC egress marking systems
- Must be continuously visible along the exit path
- Requires exposure to ambient lighting to maintain photoluminescent charge
- Must be securely mounted and constructed of durable, code-compliant materials
- Positioned to ensure visibility in smoke conditions where upper-level signage may be obscured
Disclaimer: The information provided is for general guidance based on NYC Building Code and common industry standards. Specific requirements may vary depending on building classification, occupancy, and jurisdiction. Always consult with a licensed professional or local authority (e.g., DOB or FDNY) to confirm compliance for your specific project.